A
Technical Guidance Manual: 14. OPEN VOLUME PER UNIT AREA 14.1 Procedure 14.1.1 Determine thickness in accordance with Section 8. 14.1.2 Determine porosity in accordance with Section 12. 14.2 Calculation 14.2.1 Calculate open volume per unit area as follows.
14.3 Report 14.3.1 Report the open volume per unit area and denote whether it was calculated from published minimum, minimum average roll or typical values. If the value was obtained from a single test, denote that fact.
|
||||||||||||||||||||||||||||||||||||||||
|
About ECTC | Directing Members | Associate Members | Links | Contact Us | Home What
are RECPs? | Uses & Results | Product
Information | Testing & Guidelines |
||||||||||||||||||||||||||||||||||||||||
|
© 1998-2002 by Erosion Control Technology Council. All Rights Reserved. Text, graphics, images, and HTML code are protected by US and International Copyright Laws, and may not be copied, reprinted, published, translated, hosted, or otherwise distributed by any means without explicit permission. Problems with the web site? Please contact lara@geosynthetica.net Erosion